- Tea Processing & Tea Manufacturing
- Food & Beverage Processing
- Agricultural & Agro-Processing
- Industrial Automation & Engineering
- Packaging & Material Handling
A tea machine CFM control panel regulates air velocity and thermal delivery during tea processing stages. Using feedback from airflow sensors and moisture monitors, the panel adjusts fan motor speeds via VFDs to maintain target CFM levels. It coordinates burner or steam valve modulation alongside fan control, eliminating temperature fluctuations that damage tea leaf quality. Microprocessor PID loops ensure precise heat regulation, preventing energy waste from over-ventilating drying chambers. The dust-sealed enclosure protects internal drives and relays from fine tea dust and humid processing environments. Overall, it lowers power operational overheads while prolonging the working life of heavy processing machinery.
| Key Attributes | |
|---|---|
| Operating Voltage | 415V 3-Phase AC (±10%), 50/60 Hz |
| Airflow Control Mechanism | Variable Frequency Drive (VFD) for Fan Speed Regulation |
| Compatible Motor Power | 5.5 kW to 75 kW |
| Temperature Sensor Inputs | PT100 RTD / K-Type Thermocouples |
| Airflow Sensing | Differential Pressure Transmitters / Pitot Tube Sensors |
| Controller Architecture | Microprocessor PLC / Digital Multi-Loop Controller |
| Product Category | Tea Processing & Industrial Automation Panel |
| Control System | PLC / HMI / Controller-Based* |
| Functions | Process Control, Motor Control & Monitoring |
| Communication | Ethernet / Modbus / Application-Specific* |
| Additional Information | |
|---|---|
| Country of Origin | India |
| Available Stock | In Stock |
| Sample Availability | No |
| Payment Terms |
|
| Port of Dispatch | Coimbatore, Tamil Nadu, India |

Controlling CFM (Cubic Feet per Minute) ensures proper air volume passes through green or withered leaves, driving consistent moisture removal without blowing light leaves out of the drying bed.
By regulating fan speed via a VFD instead of mechanical dampers, energy consumption drops according to fan affinity laws, cutting electricity usage during lower airflow requirements.
Yes, modern panels combine multi-zone PID temperature controllers with VFD airflow loops to synchronize heat delivery with fan speed.
It monitors moisture, inlet temperature, and exhaust air velocity in real time, auto-adjusting fan speeds to keep drying conditions balanced.
Yes, panels are housed in IP54 or IP55-rated dust- and moisture-sealed enclosures with filtered forced-air cooling.
Shipping fee and delivery date to be negotiated. Contact supplier now for more details.