Logo
Apparel & Fashion

Description

The FRP Induced Draft Cooling Tower is designed for industrial facilities that require reliable heat removal from recirculating water. Its induced draft mechanism uses a fan positioned near the air outlet to pull air through the tower and discharge the warmed air away from the cooling section. This arrangement supports airflow management and helps reduce the likelihood of warm discharge air being drawn directly back into the air intake when properly installed. During operation, hot water is distributed over the fill media, where it comes into contact with the moving air. Heat transfers from the water to the air, while evaporation removes additional thermal energy. The cooled water collects in the basin and returns to the connected process circuit.

Specifications

Key Attributes
Cooling Capacity50 TR
Material TypeFRP
Dimensions (LxWxH2000 mm
Fan TypeCentrifugal
Type of Cooling TowerInduced Draft Cooling Tower
Usage/ApplicationIndustrial
ShapeRectangular
Tower MaterialFiberglass Reinforced Polyester
Supply PhaseSingle Phase
Frequency40 Hz
Work Pressure3000Psi
Additional Information
Country of OriginIndia

Application

  1. Cooling condenser water in industrial chiller installations.
  2. Removing heat from process water used in chemical production facilities.
  3. Supporting temperature control in plastic processing machinery.
  4. Cooling water circuits connected to industrial heat exchangers.
  5. Managing thermal loads in power generation support equipment.
  6. Providing heat rejection for manufacturing process systems.
  7. Cooling recirculating water in industrial refrigeration plants.

Shipping & Logistics

Shipping InternationallyNo
Methods
  • Road

Company Profile

Phoenix Engineering And Cooling System
Phoenix Engineering And Cooling System, Tamil Nadu
TruCertified
IndiaTamil Nadu, India
4 yrs
Manufacturer
Turn Over

₹25 Lakhs – ₹1 Crore

Main Markets
India
Frequently Asked Questions
1
What is an induced draft cooling tower?

An induced draft cooling tower uses a fan at the air discharge side to pull air through the tower and move it across the water cooling section.

2
How does induced draft airflow benefit cooling tower operation?

It helps establish controlled airflow through the cooling section and directs the warm discharge air away from the tower outlet.

3
Why is FRP used in induced draft cooling towers?

FRP provides corrosion resistance and relatively low weight, making it suitable for many moisture exposed industrial environments.

4
What factors affect the performance of an induced draft cooling tower?

Performance depends on water flow rate, heat load, inlet and outlet water temperatures, ambient wet bulb temperature, airflow and fill condition.

5
Which maintenance checks are important for an FRP induced draft cooling tower?

Inspect the fan, motor, drive components, fill media, water distribution system, drift eliminators and collection basin regularly to identify wear, deposits or blockages.

FRP Induced Draft Cooling Tower

The FRP Induced Draft Cooling Tower uses a mechanically driven fan to draw air through the cooling section and discharge it from the tower. This airflow arrangement helps remove heat from circulating water used in industrial processes. The fibre reinforced plastic structure provides corrosion resistance and relatively low weight for suitable operating environments. Its induced draft design places the fan at the air discharge side, supporting controlled airflow through the tower. The unit is suitable for cooling circuits where water temperature must be reduced before recirculation to connected equipment.

Min. Order Quantity: 1 piece

Shipping

Shipping fee and delivery date to be negotiated. Contact supplier now for more details.

Shipping InternationallyNo
Phoenix Engineering And Cooling System
TruCertified
IndiaTamil Nadu, India
Manufacturer

More Products From Supplier