Logo
Apparel & Fashion

Description

Cooling Tower Fans form an important part of mechanical draft cooling systems, where controlled airflow supports the transfer of heat from water to the surrounding air. Axial fans are commonly used because they move large volumes of air along the fan shaft, making them suitable for many cooling tower configurations. The fan assembly may include blades, a hub, a shaft, a motor and a transmission system, depending on the equipment design. Blade materials and profiles vary according to the required strength, corrosion resistance and operating environment. During operation, the rotating blades draw or discharge air through the tower, assisting the cooling process and helping carry away heat and water vapour.

Specifications

Key Attributes
Fan Capacity50 TPH
Fan Size600 mm
Material TypeFRP
Fan Diameter900 mm
Fan Speed960 RPM
Airflow Capacity25000 m³/h
Motor Power3.7 kW
Operating Voltage415 V
Frequency50 Hz
Additional Information
Country of OriginIndia

Application

  1. Moving air through mechanical draft cooling towers in industrial plants.
  2. Supporting heat rejection in power generation cooling systems.
  3. Maintaining airflow in cooling towers serving central HVAC chillers.
  4. Providing air movement for process water cooling in chemical plants.
  5. Supporting cooling operations in steel and metal processing facilities.
  6. Assisting heat removal in industrial refrigeration installations.
  7. Replacing worn or damaged fan assemblies during cooling tower maintenance.

Shipping & Logistics

Shipping InternationallyNo
Methods
  • Road

Company Profile

Phoenix Engineering And Cooling System
Phoenix Engineering And Cooling System, Tamil Nadu
TruCertified
IndiaTamil Nadu, India
4 yrs
Manufacturer
Turn Over

₹25 Lakhs – ₹1 Crore

Main Markets
India
Frequently Asked Questions
1
What is the function of a Cooling Tower Fan?

It moves air through the cooling tower to support heat transfer and evaporation, helping reduce the temperature of circulating water.

2
What is an axial cooling tower fan?

An axial fan moves air parallel to its rotating shaft and is commonly used where high airflow is required through a cooling tower.

3
Which factors affect cooling tower fan performance?

Fan diameter, blade design, rotational speed, airflow resistance, motor capacity and tower configuration all influence performance.

4
How can cooling tower fan problems be identified?

Unusual noise, excessive vibration, reduced airflow, damaged blades and abnormal motor temperatures may indicate a problem requiring inspection.

5
What maintenance is required for cooling tower fans?

Maintenance typically includes checking blade condition, fasteners, alignment, vibration, motor operation and drive components according to the manufacturer's instructions.

Cooling Tower Fans

Cooling Tower Fans are used to move air through cooling towers to support heat removal from circulating water. They create the airflow needed for effective contact between air and water, helping maintain the required cooling process. Depending on the design, these fans may use axial blades, a central hub, a drive motor and a gearbox or direct-drive arrangement. Blade geometry and fan diameter influence airflow, operating efficiency and noise levels. Cooling tower fans are selected according to tower dimensions, required airflow, static pressure and operating conditions.

Min. Order Quantity: 1 piece

Shipping

Shipping fee and delivery date to be negotiated. Contact supplier now for more details.

Shipping InternationallyNo
Phoenix Engineering And Cooling System
TruCertified
IndiaTamil Nadu, India
Manufacturer

More Products From Supplier